Run the engine and shift the transmission into forward and reverse one/two times.
Universal generator oil cap full#
Refill with the proper lubricant to the full mark on the transmission dipstick. Lubricating oil and combustion deposits combine to produce harmful chemicals which can reduce the life of internal engine parts.ĭrain the lubricant from your transmission and/or V-Drive. Run the engine and check for proper oil pressure and insure that there are no leaks.ĭo not leave old engine lubricating oil in the sump over the winter lay-up period. specification recommended in your Operator's Manual.
Universal generator oil cap manual#
Fill the sump with the correct amount of oil for your engine model (Ref: Operator's Manual or Technical Manual). When installing the new oil filter, be sure to apply a small amount of oil on the sealing "O" ring at the base of the filter. Remove and replace the oil filter place some paper towels and a plastic bag around the filter to catch the oil while removing it. With the engine warm, drain ALL the lubricating oil from the oil sump. Operate the engine to insure complete circulation throughout the system. Should more antifreeze be needed, drain an appropriate amount from the engine block and add a more concentrated mixture. This solution should be checked to insure proper freeze protection. This solution may require a higher concentration of antifreeze, depending on the area's winter climate. The use of a 50-50 solution of antifreeze and fresh water is recommended for use in the fresh water cooling system year round.
Universal generator oil cap generator#
Below is a checklist of items to be performed on your diesel engine or your generator for winter lay-up. Many owners rely on their boat yards to winterize their engines or generators for them, while some owners prefer to accomplish this task themselves. Westerbeke recommends that generators not being used regularly be exercised a minimum of once per month. D-Net generators should power down the DC circuit breaker and NMEA-2000 network power to prevent battery drain when being stored for extended periods.

After the cool down period, the generator can be shut down. This step is especially important for turbocharged engines. Run the generator for 5-10 minutes at no load or a very light load to allow the engine to cool and stabilize the temperature. Run the generator at this load for 1 hour. Once the generator has reached a stable operating temperature, apply load at 70-85% of the generators rated capacity. This normally takes about 5 to 10 minutes, but can vary depending on the size of the generator and ambient conditions. Next, start and run the generator until fully warmed up. Perform all recommended procedures and checks. Westerbeke recommends the following exercise program be performed monthly for diesel generators: Before starting the generator, refer to the Operator’s Manual for The Daily Routine and Maintenance Schedule.
Universal generator oil cap free#
Following the procedures on lay-up will help insure trouble free operation when the generator is brought back into service.

If the generator is going to be stored for extended periods without being exercised, please refer to the Lay-Up and Recommissioning section of the Operator’s Manual for the generator.

The following are the recommendations for exercising Westerbeke diesel generators during extended periods of non-use.